An ultrasonic level transmitter sends sound pulses to the liquid surface and measures the echo time to calculate level – non-contact, easy to install and economical for water tanks, treatment basins, wells and open channels. Ranges 5 – 70 m, 0.25 – 0.5 % accuracy, 4–20 mA and relay outputs. ISE supplies ultrasonic level transmitters in line with European EN 61326-1 and EN 60529.

How an ultrasonic level transmitter works

The transducer emits an ultrasonic pulse and receives the surface echo: d = c·t/2. The speed of sound varies with air temperature, so the device compensates temperature; there is a dead zone near the transducer. Vapour, foam or heavy dust attenuate the echo – then choose a radar level transmitter.
Specifications (integrated and split types)
| Specifications | ||
| Function | Integrated type | Split type |
| Range | 5m, 10m, 15m, 20m, 30m, 40m, 50m | 5m, 10m, 20m, 30m, 40m, 50m, 60m, 70m |
| Accuracy | 0.25%-0.5% | 0.25%-0.5% |
| Resolution | 3mm or 0.1%(Max of them) | 3mm or 0.1%(Max of them) |
| Display | English LED | English LED |
| Output | Four-wire 4~20mA/510Ωload | 4~20mA/510Ωload |
| Two-wire 4~20mA/250Ω load | ||
| Relay output | Two groups: | Two groups for single channel |
| AC 250V/ 8A or DC 30V/ 5A | Four groups for double channels | |
| Status can be programmed | AC 250V/ 8A or DC 30V/ 5A | |
| Status can be programmed | ||
| Supply | Standard:24VDC | Standard:220V AC+15% 50Hz |
| Optional: 220V AC+15% 50Hz | Optional:24VDC or 120mA | |
| Customize:12VDC or battery | ||
| Ambient | LED : -20~+60℃, | LED : -20~+60℃, |
| Probe temperature | Probe : 20~+80℃ | Probe : 20~+80℃ |
| Communication | Option:485,232 Communication | Option:485,232 Communication |
| (manufactures agreement) | (manufactures agreement) | |
| Protection | LED: IP65, | LED: IP65, |
| Probe: IP68 | Probe: IP68 | |
| Cable | No | standars:10m longest:100m |
| Probe selection | According to the range and the probe type | According to the range |

Choosing the right level technology

Applications
- Clean water tanks, wastewater basins, sumps, wells.
- Open-channel flow (with flumes).
- Non-volatile chemical tanks, dry grain silos (short range).
Installation
- Transducer perpendicular to the surface, away from filling streams and obstacles.
- Maximum level must stay below the dead zone.
- Shade from direct sun to reduce temperature error.
Reference standards
| Standard | Scope |
|---|---|
| EN 61326-1 | EMC |
| EN 60529 | IP65 (display), IP68 (probe) |
| ATEX 2014/34/EU | Explosion-proof versions (optional) |