A radar level transmitter sends 26 GHz microwaves to the liquid surface and measures the echo time to calculate level – non-contact and unaffected by temperature, pressure, vapour or dust. Ranges up to 30 m or 70 m, ±3 mm accuracy, 4–20 mA/HART and RS485 Modbus output. ISE supplies radar level transmitters compliant with European standards ETSI EN 302 372 and EN 61326-1.

How a radar level transmitter works

The device emits microwave pulses, receives the surface echo and calculates distance d = c·t/2; level = tank height − d. Because microwaves travel at the speed of light, the result is practically independent of temperature, pressure and gas composition.
Radar level transmitter specifications
| Parameter | Value |
|---|---|
| Range | 30 m, 70 m |
| Connection | Thread, flange |
| Temperature | −40 … 250 °C |
| Pressure | −0.1 … 4.0 MPa (flat flange); −0.1 … 0.1 MPa (universal flange) |
| Accuracy | ±3 mm, ±10 mm |
| Protection | IP67 |
| Frequency | 26 GHz |
| Output | 4–20 mA/HART (2/4-wire), RS485 Modbus |

Choosing the right level technology

Applications
- Chemical, oil and solvent tanks; tanks with vapour or high temperature.
- Water tanks, wastewater basins, wells.
- Solids silos (solids radar versions).
Installation
- Avoid the tank centre (focused echoes) and the filling stream.
- Keep clear of the wall per the antenna beam angle; avoid obstacles in the beam.
- Short nozzle, antenna protruding below the nozzle.
Reference standards
| Standard | Scope |
|---|---|
| ETSI EN 302 372 | Tank level probing radar (TLPR) |
| ETSI EN 302 729 | Level probing radar in open air (LPR) |
| RED 2014/53/EU | Radio Equipment Directive |
| EN 61326-1 | EMC |
| ATEX 2014/34/EU | Explosion-proof versions (optional) |
Related products
Contact ISE
EQUIPMENT INDUSTRIAL SOLUTION CO., LTD (ISE) – Ho Chi Minh City, Vietnam.
Contact us: Sales +84 909 617 185 – Technical +84 979 117 185 – Email: [email protected]