The KTE6000 / KTU6000 industrial pressure transmitters from First Sensor are OEM pressure sensors for a wide range of industrial gases and liquids, with ranges from 250 mbar to 400 bar (5 to 6000 psi) in gauge or absolute versions. Outputs include 4–20 mA, 0–10 V, 0.5–4.5 V, 0–5 V and 1–6 V; wetted parts are 316L stainless steel with an Al₂O₃ ceramic diaphragm; IP65 protection, CE marked and EMC compliant to EN 61326-1.
With compact size, standard DIN connector, multiple threads (G1/4″, G1/2″, 1/4″ NPT, G3/4″ flush diaphragm) and field interchangeability, the KTE6000/KTU6000 is a reliable choice for machine builders, hydraulics and pneumatics, pumps, compressors and factory automation. Equipment Industrial Solution Co., Ltd (ISE) supplies all ranges, outputs and connections and helps you select the right code.
Key features of the KTE6000 / KTU6000
- Wide range: 250 mbar to 400 bar (5 to 6000 psi), gauge, sealed gauge or absolute.
- Compatible with many industrial gases and liquids: water, hydraulic oil, compressed air, inert gases…
- Five output options: 0–10 V, 0.5–4.5 V, 0–5 V, 1–6 V or 4–20 mA.
- Field interchangeable – no recalibration needed when replacing a sensor.
- Durable materials: stainless steel 1.4404 (316L), Al₂O₃ ceramic, NBR or Viton (FKM) seals.
- Reverse-polarity protected, 10 g vibration (5–500 Hz), 50 g shock.
- Fast response: 5 ms (35 ms for ranges up to 350 mbar).
- EMC to EN 61326-1, CE marked, IP65 (NEMA 4X) stainless housing.
KTE6000 industrial pressure transmitter specifications
| Parameter | Value |
|---|---|
| Range | 250 mbar … 400 bar (5 … 6000 psi) |
| Pressure type | Gauge (up to 50 bar), sealed gauge (above 50 bar), absolute (1 – 50 bar) |
| Output | 0–10 V; 0.5–4.5 V; 0–5 V; 1–6 V; 4–20 mA |
| Non-linearity + hysteresis + repeatability (BSL) | ±0.1 % FSO typ., ±0.3 % FSO max. |
| Long-term stability (1 year) | ±0.1 % FSO typ., ±0.3 % FSO max. |
| Response time (10–90 %) | 5 ms (35 ms for ranges up to 350 mbar) |
| D/A resolution | 11 bit |
| Wetted materials | Stainless steel 1.4404 (316L), Al₂O₃ ceramic, NBR or Viton (FKM) |
| Housing | Stainless steel, IP65 (DIN EN 60529, NEMA 4X) |
| Weight | Approx. 200 g |
Supply and limits
| Parameter | Value |
|---|---|
| Supply (reverse-polarity protected) | 0–10 V output: 13…32 V; 1–6 V: 9…32 V; 0.5–4.5 V and 0–5 V: 8…32 V; 4–20 mA: 7…32 V |
| Max. load current (voltage output) | 1 mA |
| Proof pressure | 1.5 × range (400 bar / 6000 psi types); 2 × range (other types) |
| Storage temperature | −40 … 85 °C |
| Media temperature | −25 … 85 °C |
| Ambient (electronics) temperature | −25 … 85 °C |
| Compensated range | 0 … 70 °C |
| Vibration (5–500 Hz) | 10 g RMS |
| Mechanical shock | 50 g |
General characteristics (Vs = 15 V, 25 °C, 50 % RH)
| Characteristic | Typical | Maximum |
|---|---|---|
| Thermal effect (0…70 °C) – zero | ±0.03 %FSO/°C (ranges ≤ 1 bar), ±0.02 %FSO/°C (others) | ±0.06 / ±0.04 %FSO/°C |
| Thermal effect (0…70 °C) – span | ±0.02 %FSO/°C | ±0.04 %FSO/°C |
| Thermal effect (−25…0 °C, 70…85 °C) | ±0.03 %FSO/°C (zero and span) | – |
| Non-linearity, hysteresis, repeatability – ± range types (KT…6N…) | ±0.2 %FSO | ±0.5 %FSO |
| Non-linearity, hysteresis, repeatability – other types | ±0.1 %FSO | ±0.3 %FSO |
| Output noise (0 < f < 1 kHz) | ±0.1 %FSO | – |
| Supply voltage effect | Zero ±0.01 %FSO/V; span ±0.02 %FSO/V | – |
Output characteristics
| Output | Zero | Full-scale span | Current consumption |
|---|---|---|---|
| 0–10 V (RL > 100 kΩ) | 0 V (max. 0.1 V) | 10 V (9.9 – 10.1 V) | 4 mA |
| 0.5–4.5 V (RL > 100 kΩ) | 0.5 V (0.45 – 0.55 V) | 4 V (3.95 – 4.05 V) | 4 mA |
| 0–5 V (RL > 100 kΩ) | 0 V (max. 0.05 V) | 5 V (4.95 – 5.05 V) | 4 mA |
| 1–6 V (RL > 100 kΩ) | 1 V (0.95 – 1.05 V) | 5 V (4.95 – 5.05 V) | 4 mA |
| 4–20 mA (RL = 100 Ω) | 4 mA (3.9 – 4.1 mA) | 16 mA (15.9 – 16.1 mA) | 250 mW (at 20 mA) |
± range types (KT…6N…) have mid-scale zero: 5 V (0–10 V), 2.5 V (0.5–4.5 V and 0–5 V), 3.5 V (1–6 V), 12 mA (4–20 mA). Voltage outputs have max. 25 Ω output impedance. For 4–20 mA, maximum load depends on supply voltage (approx. 700 Ω at 24 V).
Electrical connection and dimensions
| Pin | Voltage output | Current output | Wire colour (cable ZK000110) |
|---|---|---|---|
| 1 | +Vs | +Vs | Brown |
| 2 | −Vs | −Vs | Yellow |
| 3 | Vout | Not used | Green |
| ⏚ | Housing | Housing | White and drain |
- DIN EN 175301-803 A connector and gasket supplied.
- Moulded connector-cable set: ZK000110-x (x = cable length, max. 10 m).
- Body Ø27 mm, nominal length 68 mm; hex 27 mm (32 mm for G3/4″ flush diaphragm).
- For gauge types, the reference port vents to atmosphere through the connector/cable – keep the cable end open to ambient.
KTE6000 / KTU6000 ordering code
Structure: KT x M 6xxx x x x x — e.g. KTE6010GT4N: bar calibration, 0–10 bar, gauge, G1/2″, 4–20 mA, NBR seal.
| Code position | Options |
|---|---|
| Calibration | E: bar (KTE6000); U: psi (KTU6000) |
| M | mbar ranges only |
| Range KTE6000 (bar) | 250: 0…250 mbar; 350: 0…350 mbar; 500: 0…500 mbar; 001: 0…1 bar; N01: −1…+1 bar; P01: 0…−1 bar; 002; 005; 010; 016; 020; 025; 035; 050; 070; 100; 150; 200; 300; 400 = 0…2 to 0…400 bar |
| Range KTU6000 (psi) | 005; 010; 015; N15: −15…+15 psi; P15: 0…−15 psi; 030; 050; 100; 200; 300; 500; 1K0; 1K5; 2K0; 3K0; 4K5; 6K0 = 0…5 to 0…6000 psi |
| Pressure type | G: gauge (to 50 bar / 750 psi); S: sealed gauge (above 50 bar / 750 psi); A: absolute (1 bar / 15 psi to 50 bar / 750 psi) |
| Pressure port | L: 1/4″ NPT male; O: G3/4″ flush diaphragm (to 16 bar / 200 psi); Q: G1/4″ male; T: G1/2″. Others on request |
| Output | 0: 0…10 V; 1: 1…6 V; 4: 4…20 mA; 6: 0.5…4.5 V; 7: 0…5 V |
| Seal | V: Viton (FKM); N: NBR |
Applications of industrial pressure transmitters
- Hydraulics: presses, machine tools, mobile machinery – ranges up to 400 bar.
- Pneumatics and air compressors: receiver and pipeline pressure.
- Water and booster pumps with VFDs: 4–20 mA or 0–10 V feedback for constant pressure.
- OEM machine building thanks to compact size and many output options.
- HVAC, chillers, water supply and treatment, tanks and industrial pipelines.
- Vacuum and compound (−1…+1 bar) measurement.
FAQ
4–20 mA or 0–10 V?
4–20 mA transmits over long distances, rejects noise and detects broken wires (current drops to 0) – best for plants and long cables. 0–10 V or 0.5–4.5 V suit machine controllers over short distances.
Can it measure hot steam pressure?
Maximum media temperature is 85 °C. For steam, install via a siphon so the steam condenses and the sensor stays below 85 °C.
When should the G3/4″ flush diaphragm be used?
For viscous, dirty or scaling media to avoid blocking the pressure port; limited to 16 bar.
Related products
- CST-PT pressure transmitter
- CST305X-DPT differential pressure transmitter
- CST-MDP low differential pressure transmitter
Where to buy KTE6000 / KTU6000 industrial pressure transmitters?
EQUIPMENT INDUSTRIAL SOLUTION CO., LTD (ISE) – Ho Chi Minh City, Vietnam – supplies genuine KTE6000 / KTU6000 industrial pressure transmitters with technical consulting, fast quotation and on-site commissioning support across Vietnam and Southeast Asia.
Contact us: Sales +84 909 617 185 – Technical +84 979 117 185 – Email: [email protected]